High Voltage Gas Insulated Switchgear is used in 35kV–220kV high-voltage power systems where equipment footprint and environmental isolation are important project considerations.
Typical applications include urban underground substations, hydropower stations, data centers, and compact high-voltage substations.
The equipment is relevant where a conventional air-insulated arrangement would require more installation space.
Send Inquiry
Description
  • High Voltage Gas Insulated Switchgear is used in 35kV–220kV high-voltage power systems where equipment footprint and environmental isolation are important project considerations.
  • Typical applications include urban underground substations, hydropower stations, data centers, and compact high-voltage substations.
  • The equipment is relevant where a conventional air-insulated arrangement would require more installation space.

 

Product Specifications:

 

 

Parameter

Specification

Rated Voltage

35kV–220kV

Rated Current

630–4000A

Short-Circuit Breaking Capacity

20–50kA

Insulating Medium

SF6 gas

Structure

Fully enclosed metal construction

 

Sealed Insulation Structure:

 

 

  • SF6 gas is used as the insulating medium.
  • The main live parts are enclosed inside a fully sealed metal structure, reducing direct exposure of the internal insulation system to dust and moisture.
  • The enclosed arrangement also supports compact equipment placement within the confirmed high-voltage range.

 

Electrical Selection Range:

 

 

  • Rated voltage covers 35kV to 220kV, while rated current ranges from 630A to 4000A.
  • Confirmed short-circuit breaking capacity is 20–50kA.
  • System voltage, current, and required breaking capacity should be checked together against the project electrical design before a final configuration is released.

 

Drawing-Based Configuration:

 

 

  • Custom production may be discussed according to rated voltage, rated current, short-circuit breaking capacity, and customer technical drawings.
  • OEM/ODM service is available after the relevant authorization conditions are completed.
  • For High Voltage Gas Insulated Switchgear, technical parameters and drawings are confirmed before customized production begins.

 

Release Inspection and Export Packing:

 

 

  • Raw materials are inspected on arrival, with additional checks carried out through multiple production stages.
  • Finished equipment receives electrical performance testing, followed by 100% electrical performance inspection before packing.
  • Buyers may arrange third-party factory inspection before shipment.
  • Export equipment receives rust-prevention treatment according to the product condition and is packed in reinforced solid-wood cases for long-distance transportation.
  • Customized equipment generally requires 20–35 working days according to confirmed technical requirements.
  • Inquiry information should include system voltage, rated current, breaking capacity, quantity, site conditions, and project drawings.

 